§ 46-106. Formula for charges.
Latest version.
Industrial waste charges for discharges into the public sewers shall be calculated by the following formula:
Ci = KW (BOD/200 + SS/200)
Where
Ci = Charge to industrial user K = Percent (expressed as a decimal fraction) W = Water charge in $ BOD = Total BOD in mg/l SS = Total SS in mg/l
(Code 1978, § 24-73; Code 1993, § 82-98)